How to choose Co-Mixer for application?

 

The Co-Mixer has low concentration and high concentration two models, denoted by “L” and “H.” For application in ozone dosage, the low concentration is being used in water disinfection that requires low ozone dosages but high flow rate; while the high concentration model is being used in wastewater treatment. The performance of Co-Mixer varies with the driven pump. The gas suction rate and liquid flow rate depend on the liquid pressure (P2) that puts on the outlet of the Co-Mixer. Use the values given in the stable for estimation.

 

Model

Dimension

Pump power

HP

Inlet pressure

bar-gauge (P1)

Outlet pressure

bar-gauge (P2)

Gas suction rate

(l/min)

Liquid flow rate

(l/min)

CO15-X-Y

1.5” x 12”

2

1.2

0.2

57

140

CO15-X-Y

1.5” x 12”

2

1.2

0.5

20

113

CO15-X-Y

1.5” x 12”

2

1.2

0.8

10

105

CO15-X-Y

1.5” x 12”

3

2.4

0.2

82

217

CO15-X-Y

1.5” x 12”

3

2.4

0.5

62

182

CO15-X-Y

1.5” x 12”

3

2.4

1.0

24

171

CO15-X-Y

1.5” x 12”

5

3.4

0.2

145

221

CO15-X-Y

1.5” x 12”

5

3.4

0.5

110

221

CO15-X-Y

1.5” x 12”

5

3.4

1.0

60

204

CO30L-X-Y

3.0” x 15”

5

0.7

0.1

220

750

CO30L-X-Y

3.0” x 15”

5

0.7

0.4

30

456

CO30L-X-Y

3.0” x 15”

5

1.4

0.2

180

386

CO30L-X-Y

3.0” x 15”

5

1.4

0.5

68

267

CO30L-X-Y

3.0” x 15”

5

1.4

0.9

22

238

CO30L-X-Y

3.0” x 15”

7.5

0.95

0.2

220

1010

CO30L-X-Y

3.0” x 15”

7.5

0.95

0.5

38

743

CO30L-X-Y

3.0” x 15”

7.5

1.9

0.2

310

555

CO30L-X-Y

3.0” x 15”

7.5

1.9

0.5

150

377

CO30L-X-Y

3.0” x 15”

7.5

1.9

1.0

48

410

CO30L-X-Y

3.0” x 15”

10

2.0

0.3

500

985

CO30L-X-Y

3.0” x 15”

10

2.0

0.6

250

557

CO30L-X-Y

3.0” x 15”

10

2.0

1.0

82

287

CO60L-X-Y

6.0” x 30”

40

1.0

0.2

450

3440

CO60L-X-Y

6.0” x 30”

40

1.0

0.5

150

3340

CO60L-X-Y

6.0” x 30”

40

3.6

0.2

950

1400

CO60L-X-Y

6.0” x 30”

40

3.6

0.5

700

1820

CO60L-X-Y

6.0” x 30”

40

3.6

1.0

300

1623

CO60L-X-Y

6.0” x 30”

40

3.6

2.0

130

1700

CO80L-X-Y

8.0” x 40”

60

0.8

0.25

900

2348

CO80L-X-Y

8.0” x 40”

60

0.9

0.5

400

2732

CO80L-X-Y

8.0” x 40”

60

1.0

0.7

170

2910

CO80L-X-Y

8.0” x 40”

60

2.2

0.2

1300

1273

CO80L-X-Y

8.0” x 40”

60

2.2

0.5

800

1732

CO80L-X-Y

8.0” x 40”

60

2.2

1.0

400

1963

 

 

The gas inlet connector for CO15- is 1/4” PT male thread, for CO30- is 1/2” PT male thread, for CO60- is 1 1/4”PT female thread, for CO80- is 1 1/4” PT female thread.

Specify X and Y that denote the inlet and outlet connectors to the pipe line, for example, CO30L-flange-flange.

To prevent particles, diameter larger than 2 mm, block the Co-Mixer, install a Y-Strainer on the inlet of the pump.

 

 

 

 


[Application Information]